Demand Configuration
Purpose
example/scenarios/default/config/demand_config.xml defines the scenario demand
used by the simulator’s flight generator. Demand is a list of flows. A flow
is one demand stream: an arrival process, a path definition, and the fixed
parameters of the flights it produces.
Every element of the document is attribute-style: the repeated <flow> and
<vType> rows alike. Nesting only groups; a value is never element text.
Keys carry no unit suffix. Seconds are the implicit time unit and per-second
the implicit rate unit; a key spells out its unit only when it is not the base
unit (arrival_rate_per_hour).
Main Variables
| Variable | Unit | Default | Meaning |
|---|---|---|---|
flow@flow_id |
name | f0, f1, … |
Flow identity, and the FIRST attribute of the row. Optional; a blank id takes the document-order auto name. Must be unique |
flow@origin |
node_id |
OD flow only | Origin vertiport semantic node_id |
flow@destination |
node_id |
OD flow only | Destination vertiport semantic node_id |
flow@route |
route_id |
route flow only | The route relation the flow follows, referenced by its semantic route_id |
flow@routing_mode |
name | inferred | OD flows only: shortest_path, route, or route_distribution. When omitted: route_distribution if the flow sets route_distribution, route if it sets routes, otherwise shortest_path |
flow@routes |
list | optional | OD flows only: comma-separated route references; requests are distributed uniformly |
flow@route_distribution |
list | optional | OD flows only: weighted route list, e.g. route_a:0.7,route_b:0.3 |
flow@arrival_model |
name | inferred | poisson, uniform, probability, or count |
flow@arrival_rate |
1/s | one arrival source required | Expected arrivals per second |
flow@arrival_rate_per_hour |
1/h | one arrival source required | The same rate expressed per hour |
flow@period |
s | one arrival source required | Deterministic headway between arrivals |
flow@probability |
probability | one arrival source required | Bernoulli probability of one request per second |
flow@count |
integer | one arrival source required | Fixed number of requests, evenly spaced over begin to end or simulation end |
flow@begin / flow@end |
s | 0 / simulation end |
Active window of the flow |
flow@vehicle_type |
name | hybrid |
Vehicle type for this flow: quadrotor, fixed_wing, hybrid, or a user-defined type |
flow@priority_class |
label | regular |
Fixed priority class label |
flow@priority_rank |
integer | 0 |
Higher values are scheduled before lower values |
flow@service_class |
label | "" |
Mission/service category carried onto the generated flights |
Arrival models and their parameters
There are exactly four arrival models and exactly five ways to parameterize them. There are no synonym spellings.
arrival_model |
Process | Parameter |
|---|---|---|
poisson |
Exponential headways | arrival_rate or arrival_rate_per_hour (or period as the mean headway) |
uniform |
Evenly spaced arrivals | period, or a rate that implies the headway |
probability |
Per-second Bernoulli trial | probability |
count |
A fixed number, evenly spaced over the flow window | count |
uniform is the model name for evenly spaced arrivals; period is a
parameter key. No word does double duty.
Arrival source fields are mutually exclusive: each flow defines exactly one of
arrival_rate, arrival_rate_per_hour, period, probability, or count.
Omitting arrival_model infers it from the source: a rate implies poisson, a
period implies uniform, and probability/count imply themselves.
Identity and Reference Attributes
Two naming rules govern a <flow> row:
flow_idcomes first. Write it as the first attribute of the row, so a reader sees which flow a row is before what it points at. The shipped demand files follow this order; the loader accepts any order.- An attribute that defines an identity is
<thing>_id; one that references another object is named after that object’s type, with no_idsuffix. A flow following a route saysroute="r0", while the route relation itself carriesroute_id="r0", and the plural candidate list isroutes="r1,r2". The retiredroute_id/route_idsspellings on a flow are rejected with the replacement named.
A row that is about an object stays keyed by that object’s identity:
<corridor corridor_id="c3"> in corridor_overrides and
<element element_id="c3"> in an operation strategy. route_distribution also
keeps its name: it is a weighted distribution literal (r1:0.7,r2:0.3), not a
single reference.
How a flow declares its path
A flow declares its path in exactly ONE of two ways:
- OD flow —
origin+destination. The simulator derives the path at request time (shortest travel time by default, or one of the route-choice modes throughrouting_mode). - Route flow —
route. The flow follows that route relation exactly.
Neither form, or both forms on the same flow, is a hard error naming the flow:
the path definition would be ambiguous and there is no sensible default. A
route flow must NOT carry origin/destination — a route already carries its
endpoints — and routing_mode on a route flow is meaningless (one warning, then
ignored).
Typical Example
<demand_config>
<flows>
<!-- OD flow: the simulator derives the path. -->
<flow flow_id="mair_to_mm_shortest" origin="M-Air" destination="Michigan Medicine"
arrival_model="poisson" arrival_rate_per_hour="140"/>
<!-- OD flow choosing between two route relations. -->
<flow flow_id="nc_to_cc_spread" origin="North Campus" destination="Central Campus"
arrival_model="uniform" arrival_rate_per_hour="220" vehicle_type="hybrid"
routing_mode="route_distribution"
route_distribution="nc_to_cc_main:0.8,nc_to_cc_alt:0.2"/>
<!-- Route flow: follows the named route, no origin/destination. -->
<flow flow_id="mm_express_shuttle" route="mair_to_mm_express"
arrival_model="uniform" period="120" vehicle_type="quadrotor"/>
<!-- A second flow over the SAME route, with its own arrival process. -->
<flow flow_id="mm_express_medical" route="mair_to_mm_express"
arrival_model="poisson" arrival_rate_per_hour="6"
priority_class="medical" priority_rank="10"
service_class="medical_delivery"/>
</flows>
</demand_config>
Flow identity
flow_idis optional. Blank ids take the auto namef0,f1, … assigned in document order over the single<flows>list. The OSM-format primitives (id,lat,lon,k,v,ref) keep their bare names in the network file; a demand flow is ours, so its identity attribute isflow_id.- Ids must be unique. A duplicate — between two explicit ids, or between an explicit id and an auto-generated one — is a hard error.
- The id is functional, not decorative: it names the flow in every demand
diagnostic, and every generated request carries it (
demand_id). The preflight-schedule output writes it as thedemand_idattribute of each<flight>row, so a schedule can be grouped by flow even when several flows share one route.
Notes
- Each flow is an independent demand stream with its own arrival model.
- Flows over the same OD pair stack additively. Two identical
20flights/hour OD flows load as40flights/hour for that OD. - Flows with the same path but different fixed parameters remain distinct
streams. For example one
quadrotorflow and onehybridflow generate both vehicle types on that path. - The aggregate scenario rate is the sum of all configured flow rates. There is no aggregate fallback: a scenario with no flows simply runs empty.
- Unknown flow attributes are rejected. Use the documented fields rather than ad hoc attributes.
- Retired demand fields (such as a flow’s
route_id) and retired sections (such as<od_demand>or<traffic>) are rejected with a message naming the replacement; Upgrading Older Scenarios lists them all. A child-element value anywhere in the document is rejected with the attribute-style spelling of the same element.
Vehicle types
A vehicle type is ONE attribute-style <vType> row inside <vTypes>, in the
same demand document as the flows that reference it. The two belong together:
<vTypes> says which vehicles exist, <flows> says how many of each fly.
<vType> is the one place to set a vehicle parameter: mass, battery, speed and
acceleration limits, response time constants, power coefficients, inertia, drag
and attitude limits. A per-vehicle performance.* or dynamics.* key in
simulation_config.xml fails to load with the <vType> row that replaces it;
see
Vehicle Parameters Moved to vType.
vehicle_type is both the row’s identity and the name that a
<flow vehicle_type="..."> or a corridor vehicle_access tag uses to
reference the type.
Performance and dynamics fields share one flat row because the two field sets are disjoint; the loader splits them apart on registration.
The section does two different jobs, and which fields are REQUIRED depends on which one you are doing.
Overriding a built-in type: write only what changes
Naming a built-in type (quadrotor, fixed_wing, hybrid) — or any type
already registered — overrides only the fields the row lists and inherits every
other parameter from that type’s built-in profile. This is the common case, and
it is why the row is usually one or two attributes long:
<vTypes>
<!-- Every parameter this row does not name keeps its built-in hybrid value. -->
<vType vehicle_type="hybrid" mass="32.0" hover_power="3100.0"/>
</vTypes>
That row changes mass from 25 to 32 and hover_power from 2600 to
3100 W, and leaves the other 29 performance and dynamics parameters exactly as
the built-in defines them: state the difference, not the whole type. Of the
two, only hover_power changes the run (more energy per mission); mass is
stored but has no effect yet, see
Fields with no effect on motion or energy yet.
Nothing is required beyond vehicle_type when overriding, so there is no minimum
row. A row is not additive across parameters it does not name and it never zeroes
an unnamed field.
Defining a NEW type: the field set must be complete
A row naming a type that does not exist yet has nothing to inherit from, so it
must carry every performance and dynamics field, and a missing one is an error
naming the field. The simulator needs the complete set to construct three things:
the performance envelope, the energy model, and the 6-DOF true-state model. The
Required for a new type column of the tables below is the authoritative list.
label is optional in both cases, and max_airspeed is optional even for a new
type — see the table note.
XSD 1.0 cannot express “required only when the name is new”, so the schema marks
only vehicle_type as required and the loader is the authority on the rest. The
rejection names every missing field at once.
Registration rules
- A row naming a built-in or already-registered type overrides only the fields it lists; every other parameter is inherited.
- A row naming a NEW type must carry the complete performance and dynamics field sets. A missing field is an error naming the field.
- A row without
vehicle_typeis an error. - A row may not be named after an alias of a built-in type (
quad,multirotor,multi_rotor,fixedwing,vtol,hybrid_vtol,passenger_evtol,emergency). A flow may use these names for the built-in, so as a row name they would change that built-in rather than define a new type; the row is an error. Case and-/_do not matter:Hybridandfixed-wingname the built-ins. - A row carrying an attribute that is not a profile field is an error naming the attribute, so a typo in a parameter name cannot produce a type that only looks configured.
- A non-numeric value produces one warning and the field is dropped: an override keeps the inherited value, and a new type reports the field as missing.
Registered types are available alongside the built-ins. Absent the section,
nothing changes. Corridor-level vehicle_access tags reference built-in or
user-defined type names:
vehicle_access=quadrotor,heavy_cargo
Identity fields
| Attribute | Unit | Required | Meaning |
|---|---|---|---|
vehicle_type |
name | always | The type name flows and vehicle_access reference |
label |
text | never | Display name; defaults to a title-cased vehicle_type |
Fields with no effect on motion or energy yet
Every profile carries mass, payload, inertia_xx, inertia_yy,
inertia_zz, drag_coefficient_x, drag_coefficient_y, drag_coefficient_z
and reference_area, a new type must state them, and an override of them is
accepted and stored. In this release, however, none of them changes how a
vehicle moves or how much energy it uses, even set per type:
- The autopilot response is modelled as a closed-loop net acceleration toward
the commanded speed, so
massand the surrogate drag (drag_coefficient_*,reference_area) cancel out of the force balance. Changing them moves results only by floating-point rounding. payloadandinertia_*are not read by any model.
They are placeholders for a later thrust-drag and attitude model. To change
energy use, set hover_power and the *_power_coeff fields (and
battery_capacity for state of charge); to change how a vehicle flies, set the
speed, acceleration, rate, response-time and attitude fields.
The complete parameter set, with every built-in default
The table below is GENERATED from loft.models.vehicle by
tools/generate_doc_tables.py, so it cannot drift from the registry the
simulator actually reads. Do not edit it by hand; CI fails when it is stale.
max_airspeed is recognised but not required even for a new type: it is the
ABSOLUTE speed ceiling, and a profile that omits it falls back to
max_speed_factor * cruise_speed, which is a ratio of a scenario knob and can
therefore fall below the profile’s own min_airspeed. Declaring it is how a
profile states an envelope no scenario setting can invert. No built-in declares
one.
label is the only non-numeric field and the only one with a fallback (a title-cased vehicle_type); the built-ins carry quadrotor = Quadrotor, fixed_wing = Fixed-wing, hybrid = Hybrid VTOL.
Performance fields
| Field | Unit | Required for a new type | quadrotor |
fixed_wing |
hybrid |
|---|---|---|---|---|---|
battery_capacity |
J | yes | 7200000 |
12000000 |
18000000 |
climb_power_coeff |
ratio | yes | 250 |
320 |
380 |
cubic_speed_power_coeff |
ratio | yes | 1.2 |
0.35 |
0.6 |
hover_power |
W | yes | 1800 |
900 |
2600 |
mass |
kg | yes | 10 |
18 |
25 |
max_accel |
m/s^2 | yes | 10 |
10 |
10 |
max_climb_rate |
m/s | yes | 4 |
3 |
3.5 |
max_decel |
m/s^2 | yes | 10 |
10 |
10 |
max_descent_rate |
m/s | yes | 3 |
2.5 |
3 |
max_speed_factor |
ratio | yes | 1.2 |
2 |
1.8 |
max_turn_rate |
deg/s | yes | 20 |
10 |
14 |
max_vertical_accel |
m/s^2 | yes | 10 |
10 |
10 |
min_airspeed |
m/s | yes | 0 |
12 |
0 |
payload |
kg | yes | 0 |
2 |
4 |
quadratic_speed_power_coeff |
ratio | yes | 8 |
4 |
5.5 |
speed_response_time_constant |
s | yes | 2 |
3 |
2.5 |
turn_power_coeff |
ratio | yes | 35 |
55 |
50 |
vertical_speed_response_time_constant |
s | yes | 2 |
3 |
2.5 |
max_airspeed |
m/s | no | (unset) | (unset) | (unset) |
Dynamics fields
| Field | Unit | Required for a new type | quadrotor | fixed_wing | hybrid |
| — | — | — | — | — | — |
| attitude_damping_ratio | ratio | yes | 0.9 | 0.8 | 0.85 |
| attitude_time_constant | s | yes | 0.45 | 0.8 | 0.65 |
| drag_coefficient_x | ratio | yes | 0.9 | 0.18 | 0.35 |
| drag_coefficient_y | ratio | yes | 0.9 | 0.8 | 0.75 |
| drag_coefficient_z | ratio | yes | 1.1 | 0.9 | 0.9 |
| inertia_xx | kgm^2 | yes | 0.35 | 0.9 | 1.2 |
| inertia_yy | kgm^2 | yes | 0.35 | 1.4 | 1.6 |
| inertia_zz | kg*m^2 | yes | 0.65 | 2 | 2.4 |
| max_body_rate | deg/s | yes | 120 | 70 | 90 |
| max_control_accel | m/s^2 | yes | 10 | 10 | 10 |
| max_pitch | deg | yes | 25 | 15 | 20 |
| max_roll | deg | yes | 25 | 35 | 30 |
| reference_area | m^2 | yes | 0.18 | 0.75 | 0.65 |
Routes are standalone paths
A route is a path, not demand: an OSM relation with type=air_route whose ordered
members are corridor ways, each starting where the previous one ends
(head-to-tail, in the way drawing direction). It carries no arrival process, no
vehicle type, and no schedule — those belong to the flows that reference it, and
several flows may reference the same route.
- A route must start and end at vertiports.
- For OD flows with
routing_mode=routeorroute_distribution, every referenced route must connect the configured origin and destination directly through the airborne corridor network. - If no airborne corridor path exists between two configured vertiports, the simulator prints a warning naming the flow and skips it. Intermediate vertiport land-and-relaunch transfers are not considered a connected OD path.
- OD and route flows mix freely in one file. Their arrival processes stay
independent of whether the operation strategy selects
4d_volume,4d_volume_opt,capacity_limited_departure,element_centric_dcb, or no strategic model. - Routes are created in LOFT-Edit: select the corridor ways in order, then right-click the map and choose Create Route (one way) or Create Route from Selection.
Design notes
Both naming rules match SUMO. SUMO’s <route id="r0"> defines a route and
<vehicle route="r0"> references one; a flow row makes the same split with
route_id on the route relation and route on the flow. A row that is about
an object (<corridor corridor_id="...">, <element element_id="...">) is
keyed by that object’s identity, which is the same line SUMO draws between
<edgeData id="..."> and <vehicle route="...">.
flow_id first. tools/check_conventions.py RULE-11 enforces the
position in every demand file under example/ and tests/data/. The loader
accepts any order on purpose: XML attribute order is not semantic, and a
machine-written file must not be able to become unreadable-but-valid.
<vType> and its identity. The element name is SUMO’s <vType>, and an
override row states the difference from the type it names, the way a SUMO
vType relates to the vType it inherits from. The identity attribute is not
SUMO’s bare id: this project spells identities after the thing they
identify, the same divergence route_id makes, so vehicle_type is both the
definition’s identity and the reference spelling.